Description
Succeeding the channel settings of MWRI-I,
Micro-Wave Radiation Imager -Rainfall Mission (MWRI-RM) has enhanced observation abilities with
additional channels and improvements in calibration accuracy, observation sensitivity, positioning
accuracy and operational lifetime.
| Satellite |
FY-3G
|
| No. Channels |
13 |
| Dynamic range |
3~340K |
| Main-beam efficiency |
≥95% |
| Channel registration |
≤2km (0.5km expected) |
| Swath width |
800km |
| Scan period |
three modes: 1.7s, 1.8s, 2.0s |
| Scan error |
1ms (continuous in 30 minutes) |
Characteristics
| Center frequency (GHz) |
Polarization |
Bandwidth (MHz) |
Frequency stability (MHz) |
Sensitivity (K) |
Minimum/expected accuracy (K) |
| 10.65 |
V,H |
180 |
10 |
0.5 |
0.8 / 0.8 |
| 18.7 |
V,H |
200 |
10 |
0.5 |
0.8 / 0.8 |
| 23.8 |
V,H |
400 |
15 |
0.5 |
0.8 / 0.8 |
| 36.5 |
V,H |
900 |
20 |
0.5 |
0.8 / 0.8 |
| 50.30 |
V,H |
400 |
25 |
0.5 |
0.8 / 0.8 |
| 52.61 |
V,H |
400 |
25 |
0.5 |
0.8 / 0.8 |
| 53.24 |
V,H |
400 |
25 |
0.5 |
0.8 / 0.8 |
| 53.75 |
V,H |
400 |
25 |
0.5 |
0.8 / 0.8 |
| 89.0 |
V,H |
3000 |
25 |
0.5 |
0.9 / 0.8 |
| 118.7503±3.2 |
V |
2×500 |
25 |
0.8 |
1.2 / 0.8 |
| 118.7503±2.1 |
V |
2×400 |
25 |
0.8 |
1.2 / 0.8 |
| 118.7503±1.4 |
V |
2×400 |
25 |
0.8 |
1.2 / 0.8 |
| 118.7503±1.2 |
V |
2×400 |
25 |
0.8 |
1.2 / 0.8 |
| 165.5±0.75 |
V |
2×1350 |
30 |
0.8 |
1.2 / 0.8 |
| 183.31±2.0 |
V |
2×1500 |
30 |
0.8 |
1.2 / 0.8 |
| 183.31±3.4 |
V |
2×1500 |
30 |
0.8 |
1.2 / 0.8 |
| 183.31±7 |
V |
2×2000 |
30 |
0.8 |
1.2 / 0.8 |
Data and Products
| Satellite |
Instrument |
Datasets |
| FY-3G |
MWRI-RM |
Search
|
Calibration and Validation
MWRI-RM calibration and validation
FY-3G MWRI-RM SRF (ZIP)